Kinetrol® Clear Cone Monitor & Solenoid Valve

The optional Clear Cone provides all round high visibility position monitoring on all limit switch boxes and positioner models.
As an option Kinetrol actuator sizes 03 to 15 can be supplied with integral solenoid valves with NAMUR interface.

Description

Clear Cone Monitor

The optional Clear Cone provides all round high visibility position monitoring on all limit switch boxes and positioner models. A red/green colour coded monitor is sealed inside a robust, clear polycarbonate cover. Positioner models are marked with black printed legible angle scales.

The monitor is also available directly mounted onto actuator models 03, 05, 07, 08, 09 and 10, all EHD units and 12, 14 & 15 using an adaptor plate.

For highly corrosive environments special cover materials are available – contact Mor Endüstri Ltd. for details.

Conductive ATEX approved versions (to Category 1) are available for switch boxes and positioners – contact Mor Endüstri Ltd. for details.

For dimensions see pages 61, 62, 63 & 64 in catalogue.

Solenoid Valves

As an option Kinetrol actuator sizes 03 to 15 can be supplied with integral solenoid valves with NAMUR interface. Air is ported through the actuator body via an adaptor so no external tubing is necessary. Standard optional solenoid valves can be converted to 5 or 3 port versions by changing the valve body plate supplied with the valve.

Specifications

Coil Voltages

Electrical Connection

Manual Override

Exhaust Silencers

Hazardous Areas

Environmental Protection

Minimum Air Supply

.

AC: 50/60Hz 110V ac, 240V ac and 24V dc For other voltages contact Mor Endüstri Ltd.

DIN 43650 plug with Pg9 cable gland (6-8mm dia) as standard

extra to order

extra to order

certified solenoids are available as extras to order

to IP65 as standard

2 bar

Documents

Clear Cone Monitor and Solenoid Valve Datasheet

Description

Clear Cone Monitor

The optional Clear Cone provides all round high visibility position monitoring on all limit switch boxes and positioner models. A red/green colour coded monitor is sealed inside a robust, clear polycarbonate cover. Positioner models are marked with black printed legible angle scales.

The monitor is also available directly mounted onto actuator models 03, 05, 07, 08, 09 and 10, all EHD units and 12, 14 & 15 using an adaptor plate.

For highly corrosive environments special cover materials are available – contact Mor Endüstri Ltd. for details.

Conductive ATEX approved versions (to Category 1) are available for switch boxes and positioners – contact Mor Endüstri Ltd. for details.

For dimensions see pages 61, 62, 63 & 64 in catalogue.

Solenoid Valves

As an option Kinetrol actuator sizes 03 to 15 can be supplied with integral solenoid valves with NAMUR interface. Air is ported through the actuator body via an adaptor so no external tubing is necessary. Standard optional solenoid valves can be converted to 5 or 3 port versions by changing the valve body plate supplied with the valve.

Specifications

Coil Voltages: AC: 50/60Hz 110V ac, 240V ac and 24V dc For other voltages contact Mor Endüstri Ltd.

Electrical Connection: DIN 43650 plug with Pg9 cable gland (6-8mm dia) as standard

Manual Override: extra to order

Exhaust Silencers: extra to order

Hazardous Areas: certified solenoids are available as extras to order

Environmental Protection: to IP65 as standard

Minimum Air Supply: 2 bar

Documents

Clear Cone Monitor and Solenoid Valve Datasheet